TITLE

Research on VSC-HVDC based on modular multilevel converter technique

AUTHOR(S)
Siyu Chen; Yalou Li; Xiaobo Hu; Li Zhao; Chaoxi Chen
PUB. DATE
July 2014
SOURCE
Applied Mechanics & Materials;2014, Issue 577, p588
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This paper introduces the topology and working principle of modular multilevel converter, simplifying its equivalent circuit before obtaining virtual equipotential. On the ground of the theoretical model of equivalent circuit, MMC-HVDC could adapt the same control strategy as the traditional method. So, on the platform of PSCAD/EMTDC, an eleven level MMC Dual-infeed HVDC system is established and nearest level modulation is adopted as its control strategy to sort voltage sharing of the modules. Experimental results prove the validity of the proposed model.
ACCESSION #
99662732

 

Related Articles

  • Fault detection of HVDC cable in multiterminal offshore wind farms using transient sheath voltage. Niaki, Seyed Hassan Ashrafi; Niaki, S. Ali Nabavi; Abdoos, Ali Akbar // IET Renewable Power Generation;2017, Vol. 11 Issue 13, p1707 

    With respect to rapid growth of offshore wind power, multi-terminal HVDC system is going to be an attractive way of the power transmission for remote and large offshore wind farms. Since the HVDC cables are the vital component of the multiterminal HVDC transmission system, an accurate and fast...

  • Full-bridge MMC DC fault ride-through and STATCOM operation in multi-terminal HVDC grids. KONTOS, E.; TSOLARIDIS, G.; TEODORESCU, R.; BAUER, P. // Bulletin of the Polish Academy of Sciences: Technical Sciences;Oct2017, Vol. 65 Issue 5, p653 

    This paper investigates a control structure to enhance the DC fault ride-through capability of a full-bridge modular multilevel converter (MMC) station, while ensuring a stable controlled operation as a STATCOM during DC faults without the need for fault isolation. Taking advantage of the...

  • AC/DC multi-infeed power flow solution.  // IET Generation, Transmission & Distribution;2019, Vol. 13 Issue 10, p1838 

    Here, a novel approach is proposed to compute discrete value of converter tap position in AC/DC hybrid multi-infeed HVDC power flow solution. The approach is based on Newton-Raphson (NR) technique and sequential power flow method. An algorithm for the estimation of discrete tap position is...

  • Study of Line Commutated Converters and Capacitor Commutated Converters for HVDC Weak AC System. Rama Devi, A.; Murthy, G. R. K.; Amarnath, J. // International Journal of Applied Engineering Research;2010, Vol. 5 Issue 12, p2069 

    Operation of HVDC system using Conventional line commutated converters (LCC's) operating with weak AC systems becomes unreliable due to frequent commutation failures which can occur for any small disturbances in the AC networks. These commutation failures initiate other disturbances such as...

  • Diagnosis of Commutation Failures in HVDC System Based on Voltage or Current of the Converter Valve. Tao Liu; Tong Zhao; Liang Zou; Li Zhang; Mengqi Liu // Advanced Materials Research;2014, Vol. 960-961, p738 

    Commutation failure is one of the most common typical faults of HVDC, and it may result in subsequent commutation failures, even the outage of the HVDC system if without timely and effective regulatory measures. Trigger of the control measures depends on the rapid and accurate diagnosis of...

  • Simulation Study on Anomalous Commutation Failure in Multi-infeed HVDC Systems. Hongwei Li; Ganrong Peng // Advanced Materials Research;2014, Vol. 1008-1009, p450 

    Commutation failure theory in HVDC transmission system is proposed and its reason is analyzed. Anomalous commutation failure phenomenon related to concurrent CF or successive CF in multi-infeed HVDC transmission system is presented. Six kinds of ac system strength are used in simulating the...

  • Study on Power Supply of the Feeder Terminal Equipment. Hanmei Hu; Yajing Shi; Yanhua Zhang; Yaling Fu // Applied Mechanics & Materials;2014, Issue 672-674, p914 

    Converter transformer is one of the most important equipments of UHVDC power transmission system, its faults directly affects the safe and stable operation of DC system. The valve winding of converter transformer needs to withstand the voltage that consist of DC voltage and serious distortion of...

  • A RTDS Model for Simulating HVDC Transient Valve Voltage during Commutation Period. Luojiang Qian; Jun Yan; Peihong Zhou; Dingzhen Nie // Applied Mechanics & Materials;2014, Issue 644-650, p3705 

    This paper presents a RTDS model applied to simulate periodic commutation impulse voltage of HVDC convent valve. The model's main configure and basic parameters are matching to a typical monopole system which include 12-pulse converters of rectifier and inverter, convert-transformers, DC...

  • Realization of Automatic Power Control in HVDC Control and Protection System. Rui Zhang; Yanhong Shen; Cun Yu; Fenglong Li; Kewei Pang; Ling Zhang // Applied Mechanics & Materials;2014, Vol. 716-717, p1226 

    The paper briefly investigates the importance of power control of HVDC (high voltage direct current) control system in the HVDC projects and focus on the actual analysis and research on the realization of automatic power control in HVDC transmission. It has the important guiding significance for...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics