TITLE

DRINKING WATER TREATMENT PLANTS AND CHLORINE CONTACT TANKS

PUB. DATE
January 2014
SOURCE
WET News: Water & Effluent Treatment News;Jan2014 Supplement, p10
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
Photographs of several drinking water treatment plants and chlorine contact tanks in Great Britain including a 3,500 millimetre (mm) diameter flow meter chamber for Thames Water, 3,500 mm diameter chlorine contact tank and 500 mm diameter inter-process pipework for Anglian Water are presented.
ACCESSION #
93879739

 

Related Articles

  • Clean water for Wrangell. McLean, Mary // Alaska Business Monthly;Oct99, Vol. 15 Issue 10, p106 

    Reports the purification of drinking water through water treatment plant in Wrangell, Alaska. Primary chemical contaminants; Environmental Protection Agency regulations; Pilot plant study; Reasons for selecting the slow sand filtration technology.

  • Assessment of waterborne protozoan passage through conventional drinking water treatment process in Venezuela. Betancourt, Walter Q.; Mena, Kristina D. // Journal of Water & Health;Jun2012, Vol. 10 Issue 2, p324 

    Three drinking water treatment plants (DWTPs) differing in source water and treatment capacity were investigated for the potential passage of waterborne protozoan (oo)cysts through conventional processing. DWTP I (15,000 L/s), DWTP II (7,500 L/s) and DWTP III (4,300 L/s) provide drinking water...

  • Removal of viruses and disinfection by-products at two drinking water treatment plants in southern China. Qiang Zhang; Yan Liu; Yuanyuan Wei; Zhexue Quan; Yun Zhang; Ruihua Dai; Xiang Liu // Desalination & Water Treatment;Oct2012, Vol. 48 Issue 1-3, p221 

    The removal of viruses and disinfection by-products (DBPs) at two water plants (A and B) in a city of southern China was investigated. Coliphages MS2 and Phix174 were used as indicators of viruses. The results clearly indicated that the removal efficiency of MS2 and Phix174 was over 99% by...

  • HYGIENIC EVALUATION OF EFFECTIVENESS OF DRINKING WATER PURIFICATION FACILITIES IN SARATOV INSTITUTIONS OF SOCIAL SIGNIFICANCE. Lavrenfiev, M. V. // Saratov Journal of Medical Scientific Research / Saratovskii Nau;Apr-Jun2011, Vol. 7 Issue 2, p350 

    The purpose of the given work was studying of overall performance of the local equipments on water treating, both on superficial, and on underground sources of water supply. Material and metods. In research 60 assays of water from various superficial, underground reservoirs and planting system...

  • Toilet to Tap. D. S. // Sierra;May/Jun2008, Vol. 93 Issue 3, p28 

    The article discusses a water reclamation plant in Orange County, California that transforms sewage into drinking water. The process by which the transformation from toilet water to drinking water takes place is described. Components of this process include treatment of the water with hydrogen...

  • Reproduction of Staurastrum sp. within a water treatment plant caused by the recycle of combined sludge water and backwash water: a field investigation. Liu, Zhiquan; Xu, Yongpeng; Cui, Fuyi; Liu, Dongmei; Wang, Peng; Ma, Hua; Fan, Zhenqiang // Desalination & Water Treatment;Apr2016, Vol. 57 Issue 18, p8217 

    It is well known that the recycle of sludge water and filter backwash water in drinking water treatment plants (WTP) may cause water quality problems including suspended solids, pathogenic protozoans, dissolved organic matters, and disinfection by-products. However, it is still uncertain whether...

  • Assessing Coagulant Dosage in Full-Scale Drinking Water Treatment Plants Using Nephelometry. Cheng, Wen Po; Chen, Ping Hung; Yu, Ruey Fang; Chang, Jen Neng // Environmental Engineering Science;Mar2012, Vol. 29 Issue 3, p212 

    A nephelometric turbidimeter monitoring system (NTMS) was utilized to measure the standard deviation (SD) of turbidity of suspension solutions. Experimental results demonstrated that turbidity SD was consistent with the theory that underlay the 'turbidity fluctuation technique.' The NTMS was...

  • Fluorescence spectroscopy as a tool for determination of organic matter removal efficiency at water treatment works. Bieroza, M. Z.; Bridgeman, J.; Baker, A. // Drinking Water Engineering & Science;2010, Vol. 3 Issue 2, p63 

    The article presents a study on the application of excitation emission matrix fluorescence spectroscopy (EEMs) to assess organic matter (OM) in drinking water treatment. The study involves the use of fluorescence data of raw and clarified water which were obtained from 16 drinking water...

  • On the concept of the future drinking water treatment plant: algae harvesting from the algal biomass for biodiesel production-- a review. Ghernaout, Djamel; Ghernaout, Badiaa // Desalination & Water Treatment;Nov2012, Vol. 49 Issue 1-3, p1 

    It is well established that the drinking water treatment has several disadvantages such as it may rupture the algae, thereby releasing the taste- and odour-producing oils before the whole algae are removed from the treatment system. This review aims to present the concept of algae recovery...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics