TITLE

Is a Cementless Dual Mobility Socket in Primary THA a Reasonable Option?

AUTHOR(S)
Hamadouche, Moussa; Arnould, Hervé; Bouxin, Bertrand
PUB. DATE
November 2012
SOURCE
Clinical Orthopaedics & Related Research;Nov2012, Vol. 470 Issue 11, p3048
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Dislocation after THA continues to be relatively common. Dual mobility sockets have been associated with low dislocation rates, but it remains unclear whether their use in primary THA would not introduce additional complications. Questions/Purposes: We therefore asked whether a current cementless dual mobility socket (1) reduced the dislocation rate after primary THA, (2) provided a pain-free and mobile hip, and (3) provided durable radiographic fixation of the acetabular component without any unique modes of failure. Methods: We retrospectively reviewed 168 patients who underwent primary THA using a dual mobility socket between January 2000 and June 2002. The average age at surgery was 67 years. We assessed the rate of dislocation, hip function, and acetabular fixation on serial radiographs. Of the 168 patients, 119 (71%) had clinical and radiographic evaluation at a minimum of 5 years (mean, 6 years; range, 5-8 years). Results: A long-neck option left the base of the Morse taper uncovered in 53 hips. Four patients underwent revision for dislocation between the femoral head and the mobile insert (intraprosthetic dislocation) at a mean 6 years; all four revisions occurred among the 53 hips with an incompletely covered Morse taper. Conclusions: A current cementless dual mobility socket was associated with a pain-free and mobile hip and durable acetabular fixation without dislocations if the long-neck option was not used. However, intraprosthetic dislocation related to contact at the femoral neck to mobile insert articulation required revision in four hips. Surgeons should be aware of this specific complication. Level of Evidence: Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
ACCESSION #
82092168

 

Related Articles

  • Femoral Neck Fracture with Ipsilateral Trochanteric Fracture. Butt, Mohammad Farooq; Dhar, Shabir Ahmad; Hussain, Anwar; Ul Gani, Naseem; Kangoo, K. A.; Farooq, Munir // Internet Journal of Orthopedic Surgery;2007, Vol. 5 Issue 2, p20 

    Femoral neck fracture with ipsilateral trochanteric fracture is an uncommon association, which has been sparsely reported in literature. We report one such association wherein a successful attempt was made to preserve the femoral head by Osteosynthesis.

  • Ipsilateral femoral neck and shaft fractures: a retrospective analysis of two treatment methods. Roop Singh; Rajesh Rohilla; Narender Magu; Ramchander Siwach; Virender Kadian; Sukhbir Sangwan // Journal of Orthopaedics & Traumatology;Sep2008, Vol. 9 Issue 3, p141 

    Abstract Background  No consensus exists regarding the optimal treatment of ipsilateral femoral neck and shaft fractures. The three major issues related to these fractures are the optimal timing of surgery, which fracture to stabilize first, and the optimal implant to use. In an effort to...

  • Can we predict failure of internal fixation when treating femoral neck fractures? Kemler, M. A.; de Vries, M.; Gerard, W.J.E.; van Raay, J.J.A.M.; van der Tol, A. // European Journal of Orthopaedic Surgery & Traumatology;Jan2007, Vol. 17 Issue 1, p67 

    At present, femoral head saving surgery is reserved for femoral neck fracture patients who are either young or have suffered a minimally displaced fracture. However, even after this strict selection, an approximate failure rate of internal fixation of 15% is described in the literature. The...

  • Delayed fixation of displaced type II and III pediatric femoral neck fractures. Azam, Quamar; Iraqi, A. A.; Sherwani, M. K. A.; Abbas, M.; Alam, Afzal; Sabir, Amir Bin; Asif, Naiyer // Indian Journal of Orthopaedics;Jul-Sep2009, Vol. 43 Issue 3, p253 

    Background: Time from injury to fixation of femoral neck fractures has been postulated as a vital determinant for rate of complications; however, no prospective study is available in the English literature. Delay, unfortunately, is inevitable in developing countries. The aim of the present study...

  • Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures. Bensen, Anne; Jakobsen, Thomas; Krarup, Niels // International Orthopaedics;Jun2014, Vol. 38 Issue 6, p1241 

    Purpose: Total hip arthroplasty (THA) as primary treatment for displaced femoral neck fractures is controversial as THA is associated with higher rates of dislocation but lower rates of re-operation compared to hemiarthroplasty (HA). A dual mobility cup (DMC) design is associated with lower...

  • A calibrated patient positioning device for total hip arthroplasty. Lakshmanan, Palaniappan; Ahmed, Shahbhaz Mohammad Yasir; Woodnutt, David J. // European Journal of Orthopaedic Surgery & Traumatology;Feb2008, Vol. 18 Issue 2, p173 

    Component malpositioning in total hip arthroplasty (THA) may lead to dislocation of the prosthesis. Improper positioning of the patient on the table has been noted as one of the reasons for component malpositioning. Lateral position is routinely used for posterior approach to the hip and is also...

  • A new hinged dynamic distractor, for immediate mobilization after knee dislocations: Technical note. Zaffagnini, Stefano; Iacono, Francesco; Presti, Mirco Lo; Di Martino, Alessandro; Chochlidakis, Stavros; Elkin, Daniel J.; Giordano, Giovanni; Marcacci, Maurilio // Archives of Orthopaedic & Trauma Surgery;Nov2008, Vol. 128 Issue 11, p1233 

    Knee dislocation is always a difficult topic mainly with regard to the structures that have been damaged and the best treatment option. The purpose of this study is to describe a new dynamic external fixator (EF) to be applied after knee dislocation, in combination with posterior cruciate...

  • COMPUTERIZED NAVIGATION FOR THE INTERNAL FIXATION OF FEMORAL NECK FRACTURES. Liebergall, Meir; Ben-David, Dror; Weil, Yoram; Peyser, Amos; Mosheiff, Rami // Journal of Bone & Joint Surgery, American Volume;Aug2006, Vol. 88-A Issue 8, p1748 

    Background: Accurate placement of cannulated screws is essential to ensure secure fixation of femoral neck fractures. We compared computerized navigation and conventional fluoroscopy with regard to the accuracy of screw placement for the fixation of femoral neck fractures. Methods: We...

  • Is Patient Selection Important for Hip Resurfacing? Ryan Nunley; Craig Della Valle; Robert Barrack // Clinical Orthopaedics & Related Research;Jan2009, Vol. 467 Issue 1, p56 

    Abstract  The optimal implant option for hip arthroplasty in the young, active patient remains controversial. There has been renewed interest for metal-on-metal hip resurfacing due to improved design and manufacturing of implants, better materials, enhanced implant fixation,...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics