TITLE

The change of response of ionization chambers in the penumbra and transmission regions: impact for IMRT verification

AUTHOR(S)
González-Castaño, D.; Pena, J.; Sánchez-Doblado, F.; Hartmann, G. H.; Gómez, F.; Leal, A.
PUB. DATE
April 2008
SOURCE
Medical & Biological Engineering & Computing;Apr2008, Vol. 46 Issue 4, p373
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Significant deviations from the expected dose have been reported in the absolute dosimetry validation of an intensity modulated radiation therapy treatment when individual segments are analyzed. However, when full treatment is considered and all segment doses are added together, these discrepancies fade out, leading to overall dose deviations below a 5% action level. This contradictory behavior may be caused by a partial compensation between detector over-responding and under-responding for measurement conditions far from radiation equilibrium. We consider three treatment verification scenarios that may lead to ionization chamber miss-responding, namely: narrow beam irradiation, field penumbra location and multi-leaf collimator transmission contribution. In this work we have analyzed the response of three different ionization chambers with different active volume under these conditions by means of Monte Carlo (MC) simulation methods. Correction factors needed to convert the detector readout into actual dose to water were calculated by inserting the specific detector geometry (carefully modeled) into the simulations. This procedure required extensive use of parallel computing resources in order to achieve the desired level of uncertainty in the final results. The analysis of the simulations shows the relative contribution of each of the three previously mentioned miss-responding scenarios. Additionally, we provide some evidence on dose deviation compensation in multi-segment radiotherapy treatment verification.
ACCESSION #
31342665

 

Related Articles

  • Effect of the diaphragm of free-air ionisation chamber for X-ray air-kerma measurements. Kurosawa, Tadahiro; Takata, Nobuhisa; Saito, Norio // Radiation Protection Dosimetry;Jul2011, Vol. 146 Issue 1-3, p195 

    Free-air ionisation chambers are widely used at standards laboratories as primary standards for absolute measurements of air kerma in X-ray fields. The area of the diaphragm aperture of a free-air ionisation chambers is an important factor for absolute measurements because it defines the size of...

  • Thermal ionization in hydrogen plasma simulated using Feynman path integrals. Shevkunov, S.V. // Journal of Experimental & Theoretical Physics;Sep2007, Vol. 105 Issue 2, p404 

    Thermal ionization of hydrogen at temperatures on the order of 104–105 K and densities within 1024–1028 m−3 has been simulated using Feynman path integrals. This method has been realized for the first time under conditions of a statistical ensemble with fluctuating volume....

  • Low noise fractional NTC collisions for DSMC. Martin, Robert Scott; Cambier, Jean-Luc // AIP Conference Proceedings;Nov2012, Vol. 1501 Issue 1, p615 

    The ability to accurately simulate rare high energy collisions such as those found in ionization and combustion reactions is important to the advancement of the study of non-equilibrium behavior of these phenomena. A major difficulty for modeling these systems with particle codes is that...

  • Experimental and theoretical studies of the spatial distribution of the ionization rate in a non-self-sustained discharge controlled by a fast electron beam. Gurashvili, V.; Dzhigailo, I.; Dyatko, N.; Zanozina, E.; Kochetov, I.; Spitsyn, D.; Tkachenko, D. // Plasma Physics Reports;Jan2012, Vol. 38 Issue 1, p46 

    The spatial distribution of the current density of fast electrons and the ionization rate in a gap filled with atmospheric-pressure air under the conditions of a non-self-sustained discharge controlled by a fast electron beam were investigated. The experiments were carried out in a gas-discharge...

  • A semi-grand canonical Monte Carlo simulation model for ion binding to ionizable surfaces: Proton binding of carboxylated latex particles as a case study. Madurga, Sergio; Rey-Castro, Carlos; Pastor, Isabel; Vilaseca, Eudald; David, Calin; Garcés, Josep Lluís; Puy, Jaume; Mas, Francesc // Journal of Chemical Physics;11/14/2011, Vol. 135 Issue 18, p184103 

    In this paper, we present a computer simulation study of the ion binding process at an ionizable surface using a semi-grand canonical Monte Carlo method that models the surface as a discrete distribution of charged and neutral functional groups in equilibrium with explicit ions modelled in the...

  • Simulation Studies of Hydrogen Ion reflection from Tungsten for the Surface Production of Negative Hydrogen Ions. Kenmotsu, Takahiro; Wada, Motoi // AIP Conference Proceedings;9/26/2011, Vol. 1390 Issue 1, p134 

    The production efficiency of negative ions at tungsten surface by particle reflection has been investigated. Angular distributions and energy spectra of reflected hydrogen ions from tungsten surface are calculated with a Monte Carlo simulation code ACAT. The results obtained with ACAT have...

  • Redução de incertezas em radioterapia utilizando simulação Monte Carlo: análise espectral aplicada à correção de dose absorvida. Marques, Tatiana; Alva-Sánchez, Mirko; Nicolucci, Patrícia // Radiologia Brasileira;mar/apr2010, Vol. 43 Issue 2, p119 

    OBJECTIVE: To calculate spectra of cobalt-60 beam at water depth and correction factors for absorbed dose measurements obtained with lithium fluoride thermoluminescent dosimeters using Monte Carlo simulation. MATERIALS AND METHODS: The simulations of secondary spectra of clinical cobalt-60...

  • Monte Carlo simulations of partially ionized polyelectrolytes: Shape and distribution functions. Christos, George A.; Carnie, Steven L. // Journal of Chemical Physics;7/1/1989, Vol. 91 Issue 1, p439 

    A novel modification to the ‘‘slithering snake’’ algorithm is used to enable Monte Carlo simulations of partially ionized polyelectrolyte chains where the charged beads interact via screened Coulomb interactions. The use of ‘‘stroboscopic’’...

  • Avalanche speed in thin avalanche photodiodes. Ong, D. S.; Rees, G. J.; David, J. P. R. // Journal of Applied Physics;4/1/2003, Vol. 93 Issue 7, p4232 

    The duration of the avalanche multiplication process in thin GaAs avalanche photodiodes is investigated using a full band Monte Carlo (FBMC) model. The results are compared with those of a simple random path length (RPL) model which makes the conventional assumptions of a displaced exponential...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics