TITLE

A comparison of echocardiographic and electron beam computed tomographic assessment of aortic valve area in patients with valvular aortic stenosis

AUTHOR(S)
Lieuwe Piers; Riksta Dikkers; René Tio; Maarten van den Berg; Tineke Willems; Felix Zijlstra; Matthijs Oudkerk
PUB. DATE
December 2007
SOURCE
International Journal of Cardiovascular Imaging;Dec2007, Vol. 23 Issue 6, p781
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Abstract  The purpose of this study was to compare electron beam computed tomography (EBT) with transthoracic echocardiography (TTE) in determining aortic valve area (AVA). Thirty patients (9 females, 21 males) underwent a contrast-enhanced EBT scan (e-Speed, GE, San Francisco, CA, USA) and TTE within 17 � 12 days. In end-inspiratory breath hold, a prospectively ecg-triggered scan was acquired with a beam speed of 50–100 ms, a collimation of 2 � 1.5 mm and an increment of 3.0 mm. The AVA was measured with planimetry. A complete TTE study was performed in all patients, and the AVA was computed using the continuity equation. There was close correlation between AVA measured with EBT and AVA assessed with TTE (r = 0.60, P 2 larger than the AVA calculated with TTE measurements. EBT appeared to be a valuable non-invasive method to measure the AVA. EBT measures the anatomical AVA, while with TTE the functional AVA is calculated, which explains the difference in results between the methods.
ACCESSION #
27413750

 

Related Articles

  • Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard. I.-Chen Tsai; Yung-Kai Lin; Yen Chang; Yun-Ching Fu; Chung-Chi Wang; Shih-Rong Hsieh; Hao-Ji Wei; Hung-Wen Tsai; Sheng-Ling Jan; Kuo-Yang Wang; Min-Chi Chen; Chen, Clayton // European Radiology;Apr2009, Vol. 19 Issue 4, p857 

    The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography...

  • New modality for monitoring lung set to challenge CT, TEE. BROSKY, JOHN // Medical Device Daily;3/24/2011, Vol. 15 Issue 57, p1 

    The article reports on the launch of PulmoVista 500, a modality for functional lung imaging, developed by Draeger Medical. The monitor uses electro-impedance technology (EIT) that complements images from computed tomography (CT) and may replace invasive transesophageal echocardiography (TEE)....

  • Transesophageal Echocardiography for Detecting Intracardiac Thrombi in Embolic Stroke. Toyoda, Kazunori; Yasaka, Masahiro; Nagata, Seiki; Yamashita, Nobushige; Imakita, Satoshi; Yamaguchi, Takenori // Angiology;May1993, Vol. 44 Issue 5, p376 

    The authors studied 56 patients with cardioembolic stroke to search for intracardiac thrombi by use of transesophageal and transthoracic echocardiography. Forty consecutive patients were examined within four weeks of stroke onset and the remaining 16 in the chronic stage. They also performed...

  • Constrictive Pericarditis. Ming-Ren Chen; Shye-Jao Wu; Chun-Ho Yun // Pediatric Cardiology;Oct2009, Vol. 30 Issue 7, p1032 

    The article presents a case of a 17-year old male who had an episode of fainting after running on the playground. During examination, the patient's liver was palpable five centimeters below the right costal margin. After undergoing echocardiography, cardiac catheterization, and computerized...

  • The spectrum of radiologic findings in idiopathic arterial calcification of infancy: pictorial essay. Saigal, Gaurav; Azouz, E. Michel // Canadian Association of Radiologists Journal;Apr2004, Vol. 55 Issue 2, p102 

    Discusses radiologic spectrum associated with idiopathic arterial calcification of infancy. Computed tomography; Ultrasonography; Extensive arterial wall calcification.

  • Equipment availability and diagnostic strategies for suspected pulmonary embolism in Austria. Schibany, N.; Fleischmann, D.; Thallinger, C.; Schibany, A.; Hahne, J.; Ba-Ssalamah, A.; Herold, C. // European Radiology;Nov2001, Vol. 11 Issue 11, p2287 

    The aim of this study was to investigate equipment availability and current diagnostic strategies for suspected pulmonary embolism (PE) in Austrian hospitals. A questionnaire was sent to the medical directors of all Austrian hospitals with emergency and/or surgical, orthopedic, and medical...

  • Congenital chylous ascites. Herman, T. E.; Siegel, M. J. // Journal of Perinatology;Feb2009, Vol. 29 Issue 2, p178 

    The article presents a case study of an infant with congenital chylous ascites. Radiographs of the chest and abdomen, an abdominal sonogram, and an abdominal computerized tomography scan are presented, as is the process by which doctors arrived at the diagnosis. The article details the treatment...

  • Three-dimensional characterization of cortical bone microstructure by microcomputed tomography: validation with ultrasonic and microscopic measurements. Armelle Basillais; Sabine Bensamoun; Christine Chappard; Barbara Brunet-Imbault; Gérald Lemineur; Brice Ilharreborde; Marie-Christine Ho Ba Tho; Claude-Laurent Benhamou // Journal of Orthopaedic Science;Mar2007, Vol. 12 Issue 2, p141 

    Abstract Background  The porosity of human cortical bone is one of the major parameters conditioning bone strength. The purpose of this study was to validate the characterization of human cortical bone microarchitecture using microcomputed tomography (CT). To validate this CT...

  • The Possibilities and Limitations of Direct Digital Radiography, Ultrasound and Computed Tomography in Diagnosing Pleural Mesotelioma.  // Collegium Antropologicum;Dec2010, Vol. 34 Issue 4, p1263 

    No abstract available.

  • PERFORMANCE EVALUATION OF TWO COMPUTED RADIOGRAPHY SYSTEMS AND PATIENT DOSE IN PELVIC EXAMINATION. Elshiekh, E.; Suliman, I. I.; Habbani, F. // Radiation Protection Dosimetry;Jul2015, Vol. 165 Issue 1-4, p392 

    This study was carried out to evaluate the performance of two computed radiography (CR) units. These evaluations became necessary following the introduction of CR systems in Sudan. Evaluation of the CR systems was performed using physical image quality parameters: signal transfer property,...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics