TITLE

DOSE EVALUATION IN LUNG-EQUIVALENT MEDIA IN HIGH-ENERGY PHOTON EXTERNAL RADIOTHERAPY

AUTHOR(S)
Duchl, M. A.; Carrasco, P.; Ginjaume, M.; Jornet, N.; Ortega, X.; Ribas, M.
PUB. DATE
September 2006
SOURCE
Radiation Protection Dosimetry;2006, Vol. 120 Issue 1-4, p43
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In high-energy photon external radiotherapy treatment planning systems (TPSs) are used to calculate the dose to the target volume and the dose distribution around it. Commonly used TPSs include algorithms based on measurements in water and often fail in the estimate of dose in the presence of heterogeneities. In this study TL detectors were used to study the reliability of the Cadplan (Varian) TPS in the presence of low-density heterogeneities such as the lung for 6 and 18 MV photon beams at different field sizes. TL measurements were compared with TPS calculations and Monte Carlo simulations performed with the PENELOPE MC code. In a phantom with lung heterogeneity, TL measurements and MC simulations agreed, with an average deviation inside the lung of 2%. In contrast, TPS results overestimated the dose inside the lung, with a maximum deviation of 39% for the 18 MV photon beam and a field size of 2 × 2 cm².
ACCESSION #
23154548

 

Related Articles

  • Accurate simulation of ionisation chamber response with the Monte Carlo code PENELOPE. Sempau, Josep; Andreo, Pedro // AIP Conference Proceedings;8/10/2011, Vol. 1351 Issue 1, p155 

    Ionisation chambers (IC) are routinely used in hospitals for the dosimetry of the photon and electron beams used for radiotherapy treatments. The determination of absorbed dose to water from the absorbed dose to the air filling the cavity requires the introduction of stopping power ratios and...

  • RADIATION TRANSPORT CALCULATIONS FOR 50 MV PHOTON THERAPY BEAM USING THE MONTE CARLO CODE GEANT4. Larsson, Susanne; Svensson, Roger; Gudowska, Irena; Ivanchenko, Vladimir; Brahme, Anders // Radiation Protection Dosimetry;2005, Vol. 115 Issue 1-4, p503 

    A new thin transmission target technique for fast dose delivery using narrow scanned photon beams has been developed. High-energy, 50-100 MeV, electron beams of low emittance incident on thin low-Z targets produce narrow and intense high-energy bremsstrahlung beams. However, electrons...

  • COMPARISON OF TREATMENT PLANNING DOSE CALCULATIONS WITH MEASUREMENTS AND MONTE CARLO CALCULATIONS IN A RANDO PHANTOM. Wyatt, M.; Corredor, C.; Tamimi, M.; Miller, L. F. // Radiation Protection Dosimetry;2005, Vol. 116 Issue 1-4, p461 

    Solid tumours are often treated with external beams of photons generated by Bremsstrahlung radiation. These beams are shaped and filtered to optimise the dose to specific regions defined by the treatment plans, which may involve irradiations from multiple angles. It is important that doses to...

  • Comparison Between Two Monte Carlo Simulations of Angiographic Phantom Coupled to Silicon Strip Detector. Montafio, L.M.; Sanchez, D.; Avila, C.; Sanabria, J.; Baldazzi, G.; Bollini, D.D.; Cabal, A.; Ceballos, C.; Dabrowski, W.; García, A. Díaz; Gambaccini, M.; Giubellino, P.; Gombia, M.; Grybos, P.; Idzik, M.; Marzari-Chiesa, A.; Prino, F.; Ramello, L.; Sitta, M.; Swientek, K. // AIP Conference Proceedings;2004, Vol. 724 Issue 1, p221 

    Preliminary results of a dual energy angiography simulation using the Monte Carlo package GEANT 3.2113 are presented and compared to Monte Carlo MCNP-4C results reported before. The simulation is based on an experimental set up consisting of a Plexiglas-aluminium step wedge phantom with 4...

  • The Propagation of Laser Light in Skin by Monte Carlo-Diffusion Method: A Fast and Accurate Method to Simulate Photon Migration in Biological Tissues. Afsari Golshan, Maryam; Ghasemi Tarei, Maryam; Ali Ansari, Mohammad; Amjadi, Ahmad // Journal of Lasers in Medical Sciences;Summer2011, Vol. 2 Issue 3, p109 

    Introduction: Due to the importance of laser light penetration and propagation in biological tissues, many researchers have proposed several numerical methods such as Monte Carlo, finite element and green function methods. Among them, the Monte Carlo method is an accurate method which can be...

  • ENERGY AND ANGULAR ANISOTROPY OPTIMISATION OF A p-TYPE DIODE FOR IN VIVO DOSIMETRY IN PHOTON-BEAM RADIOTHERAPY. Greene, Simon; Price, Robert A. // Radiation Protection Dosimetry;2005, Vol. 116 Issue 1-4, p152 

    We present simulation work using the Monte Carlo code MCNPX that shows that there is a possibility of improving the silicon p-type diode as a radiation dosemeter, by altering the construction of the diode. Altering the diode die thickness can reduce the inherent angular anisotropy of the diode,...

  • A METHOD TO PERFORM MULTI-SCALE MONTE CARLO SIMULATIONS IN THE CLINICAL SETTING. Lucido, Joseph John; Antoniu Popescu, I.; Moiseenko, Vitali // Radiation Protection Dosimetry;2015 Special Isuue, Vol. 166, p356 

    In order to model the track structure of clinical mega-voltage photon beams in a reasonable time, it is necessary to use a multiscale approach incorporating a track-structure algorithm for the regions of interest and a condensed history algorithm for the rest of the geometry. This paper...

  • Dose enhancement in gold nanoparticle-aided radiotherapy for the therapeutic photon beams using Monte Carlo technique. Kakade, Nitin Ramesh; Sharma, Sunil Dutt // Journal of Cancer Research & Therapeutics;Jan-Mar2015, Vol. 11 Issue 1, p94 

    Background: Gold nanoparticle (GNP)-aided radiation therapy (RT) is useful to make the tumor more sensitive to radiation damage because of the enhancement in the dose inside the tumor region. Polymer gel dosimeter (PGD) can be a good choice for the physical measurement of dose enhancement...

  • Smart Darting Monte Carlo. Andricioaei, Ioan; Straub, John E.; Voter, Arthur F. // Journal of Chemical Physics;4/22/2001, Vol. 114 Issue 16 

    The "Smart Walking" Monte Carlo algorithm is examined. In general, due to a bias imposed by the interbasin trial move, the algorithm does not satisfy detailed balance. While it has been shown that it can provide good estimates of equilibrium averages for certain potentials, for other potentials...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library