TITLE

MICHIGAN

PUB. DATE
October 2006
SOURCE
ENR: Engineering News-Record;10/23/2006, Vol. 257 Issue 16, p52
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
The article reports on the selection of Washington Group International Inc. for the provision of engineering, procurement and construction services for a major environmental retrofit project at Detroit Edison's Monroe Power Plant in Michigan. The project includes construction of flue-gas desulphurization systems or scrubbers on the plant's generating Units 3 and 4, each of which generates about 775 megawatts.
ACCESSION #
22985611

 

Related Articles

  • Analiza zmian podaży gipsu w Polsce w Å›wietle rozwoju odsiarczania spalin w elektrowniach konwencjonalnych / Analysis of the Changes in Polish Gypsum Resources in the Context of Flue Gas Desulfurization in Conventional Power Plants. Szlugaj, Jarosław; Naworyta, Wojciech // Mineral Resources Management / Gospodarka Surowcami Mineralnymi;Jun2015, Vol. 31 Issue 2, p93 

    Twenty years ago in the Belchatow power plant in Poland the first flue gas desulfurization (FGD) were launched, in which as a byproduct a synthetic gypsum is obtained. In accordance with international commitments the desulfurization has been implemented gradually in many other domestic power...

  • Benefit Analysis and FGD Optimization for Designed Power Plant Based on Comprehensive Benefit Index System. Rui Rui; Ding Ye; Jiang Long // Advanced Materials Research;2014, Issue 1044-1046, p255 

    Taking the initial design value for target power plant as standard index values, two comprehensive benefit index systems for flue gas desulphurization (FGD) technology were formed by mean square difference method with or without the index of earning of by-product, to analyze the environmental...

  • Field test of SO3 removal in ultra-low emission coal-fired power plants. Zhang, Yang; Zheng, Chenghang; Hu, Fushan; Zhao, Haitao; Liu, Shaojun; Yang, Zhengda; Zhu, Yue; Gao, Xiang // Environmental Science & Pollution Research;Feb2020, Vol. 27 Issue 5, p4746 

    Under the extensive implementation of ultra-low emission (ULE) facilities in coal-fired power plants of China, sulfur trioxide (SO3) has received increasing attention due to its impact on human health and operation safety of power plants. However, systematic research and evaluation for...

  • CLEANING UP. Kuhar, Mark S. // Rock Products;Nov2011, Vol. 114 Issue 11, p24 

    The article focuses on the operation of Virginia-based Carmeuse Lime & Stone. For the company to create fast, efficient and safe railcar loadout operation, it uses feeders and magnets from Eriez, world leader in magnetic vibratory. The company uses the technology called flue gas desulfurization...

  • Integrating LCA and LCC study of FGD system at a thermal power plant in China. Rui Xu; Fengsheng Hou // Journal of Software (1796217X);Dec2010, Vol. 5 Issue 12, p1425 

    This paper presents the integrating Life Cycle Assessment (LCA) and Life Cycle Costing (LCC) study of the Flue Gas Desulphurization (FGD) system in Fengcheng thermal power plant in China. The FGD systems have been installed in a power generation plant to reduce the large amount of SO2 emission....

  • Constructal allocation of heat transfer area in Flue Gas Desulfurization equipment for coal-firing power plants. Lee, J.; Kim, Y. // International Journal of Energy Research;3/25/2016, Vol. 40 Issue 4, p529 

    In this paper, we report opportunities to maximize the overall heat transfer rate of a cooler and reheater by appropriately shaping the flue gas desulfurization equipment of a thermal power plant driven by coal-firing combustion. The hottest combustion gas experiences a temperature drop through...

  • Environmental Performance of a Solid Waste Monetization Process Applied to a Coal-Fired Power Plant with Semi-Dry Flue Gas Desulfurization. de Andrade Cruz, Matheus; de Paula Vieira de Castro, Rui; de Queiroz Fernandes Araújo, Ofélia; de Medeiros, José Luiz // Journal of Sustainable Development of Energy, Water & Environmen;Sep2019, Vol. 7 Issue 3, p506 

    Mixing of semi-dry flue gas desulfurization solids and fly-ash from coal-fired power plants results in a solid waste contaminated by calcium sulfite. Therefore, it becomes useless for industry and is often landfilled. To support decision-making on process configurations to monetize this solid...

  • Desulfurization Needs Increased.  // Pollution Engineering;Dec2008, Vol. 40 Issue 12, p13 

    The article presents the forecast which focuses on the growth of coal-fired power plants installing flue gas desulfurization (FGD) systems by 2020. According to McIlvaine Co., coal-fired power plants will spend $200 billion for the implementation of FGD to combustion units in the said year with...

  • Influence of flue gas desulphurisation ash on moisture damage in asphalt mixtures. Chen, J.; Wu, S.; Pang, L.; Chen, Z.; Xie, J.; Lei, M. // Materials Research Innovations;Jul2014 Supplement 4, Vol. 18 Issue S4, p81 

    Moisture damage has a significant negative impact on asphalt and the behaviour of the pavement. It exacerbates the service performance (e.g. rutting, cracking) of the asphalt mixture. This paper investigated the influence of flue gas desulphurisation ash (FGDA) on asphalt mixture moisture...