Estimates of Interventricular Septum Thickness Are Markedly Affected by the Method Used

AUTHOR(S)
Poutanen, T.; Tikanoja, T.
PUB. DATE
July 2003
SOURCE
Pediatric Cardiology;Jul2003, Vol. 24 Issue 4, p325
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Modern echocardiographic techniques allow precise measurements of interventricular septum thickness by two-dimensional echocardiography (2DE) and M-mode echocardiography. The advantage of 2DE is the more accurate estimate in cases in which the shape of the septum differs from normal. However, the usefulness of measurements by 2DE is limited due to the lack of reference values. We measured maximal septum thickness by 2DE in 168 healthy subjects aged 2 to 27 years and compared the results to those obtained by M-mode. In agreement analysis the bias ± 2 SD between 2DE and M-mode was 0.8 ± 1.7 mm (p < 0.001). Maximal septum thickness exceeded the upper normal limit (+2 SD) of the largest pediatric reference data in 14 (8%) of the healthy subjects studied. Interventricular septum thickness is greater when measured by 2DE than by M-mode. Previous M-mode reference values should be used with caution; preferably, reference data based on 2DE should be used.
ACCESSION #
17012359

 

Related Articles

  • Clinical applications of two-dimensional speckle tracking. Beynon, Rhys P.; Blessberger, Hermann; Binder, Thomas // Heart;Feb2011, Vol. 97 Issue 4, p342 

    A letter to the editor and a response by Hermann Blessberger and Thomas Binder to the letter about their articles "Two Dimensional Speckle Tracking Echocardiography: Clinical Applications" and "Non-Invasive Imaging: Two Dimensional Speckle Tracking Echocardiography: Basic Principles" in a 2010...

  • echocardiography:. Huber, Jeffrey T.; Gillaspy, Mary L. // Encyclopedic Dictionary of AIDS-Related Terminology;2000, p80 

    An encyclopedia entry for echocardiography is presented. It refers to a noninvasive technique for examining the internal structure of the heart which makes use of echoes obtained by directing beams of ultrasonic waves. The diagnostic method examines the heart by visualizing and graphically...

  • Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging. Artang, Ramin; Migrino, Raymond Q.; Harmann, Leanne; Bowers, Mark; Woods, Timothy D. // Cardiovascular Ultrasound;2009, Vol. 7, Special section p1 

    Objective: Left atrial size is an important marker for adverse cardiovascular events. There is general consensus that left atrial volume index (LAVI) is the best measurement of size. The current LAVI measurement techniques are laborious. Semi-automated measurement with a 3-dimensional...

  • Assessment of cardiac remodeling in asymptomatic mitral regurgitation for surgery timing: a comparative study of echocardiography and magnetic resonance imaging. Ozdogan, Oner; Yuksel, Alper; Gurgun, Cemil; Kayikcioglu, Meral; Yavuzgil, Oguz; Cinar, Cahide S. // Cardiovascular Ultrasound;2010, Vol. 8, p32 

    Background: Early surgery is recommended for asymptomatic severe mitral regurgitation (MR), because of increased postoperative left ventricular (LV) dysfunction in patients with late surgery. On the other hand, recent reports emphasized a "watchful waiting" process for the determination of the...

  • Increased Left Atrial Volume Index: Potent Biomarker for First-Ever Ischemic Stroke. Fatema, Kaniz; Bailey, Kent R.; Perry, George W.; Meissner, Irene; Osranek, Martin; Alsaileek, Ahmed A.; Khandheria, Buoy K.; Tsang, Teresa S.; Seward, James B. // Mayo Clinic Proceedings;Oct2008, Vol. 83 Issue 10, p1107 

    OBJECTIVE: To establish the incidence and correlation of increased left atrial volume index (LAVI) in patients with first-ever lschemic stroke. PARTICIPANTS AND METHODS: Using our institution's epidemlological database, we defined a cohort of 432 patients (cases) who underwent transthoracic...

  • Baseline normalisation of ECG signals using empirical mode decomposition and mathematical morphology. Ji, T.Y.; Lu, Z.; Wu, Q. H.; Ji, Z. // Electronics Letters;1/17/2008, Vol. 44 Issue 2, p82 

    An approach to remove baseline wander from electrocardiogram (ECG) signals, based on empirical mode decomposition and mathematical morphology, is described.

  • Antenatal screening with fetal echocardiography: when and how. Benoit, Richard M.; Copel, Joshua A. // Contemporary OB/GYN;Sep2003, Vol. 48 Issue 9, p59 

    Reviews accepted indications for recommending fetal echocardiography. Familial and genetic risk factors of congenital heart disease (CHD); Maternal factors that increase the risk of CHD in offspring; Information on fetal extracardiac abnormality.

  • Intracardiac echocardiography in the diagnosis of prosthetic valve endocarditis. Kolodner, D. Q.; Shimbo, D.; Magnano, A. R. // Heart;Sep2007, Vol. 93 Issue 9, p1120 

    The article discusses the case of a 79-year old woman who was febrile with blood cultures positive for Candida parapsilosis. The women went through intracardiac echocardiography (ICE). This woman have also undergone bypass grafting and bioprosthetic aortic valve replacement three years before...

  • Dynamic changing mass behind the left atrium. Buss, S.; Katus, H. A.; Mereles, D. // Heart;Dec2007, Vol. 93 Issue 12, p1583 

    The article presents a case study of an old woman who was investigated at the echocardiography laboratory after an acute myocardial infarction. Study shows the dynamic changing mass behind the left atrium (LA). It was found out that an undefined liquid-containing mass was observed behind the LA,...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics